Stage
number |
Stage
name |
Stage description |
Rated
power
|
Vitrified mass |
1 |
Laboratory-scale |
Engineering feasibility of the
vitrification process |
10 kW |
1-10 kg |
2 |
Pre-pilot
scale |
Development of the first power supply
prototype, of its control and of the prototype gas-effluent treatment
system |
30 kW |
50-100 kg |
3 |
Pilot
scale |
Development of a combined power supply
plant including its control and the final gas-effluent treatment system |
0.5 MW |
0.5 - 1 t |
4 |
Prototype
scale |
Design and optimization of the ISV plant
components in view of the real-scale application |
0.5 MW |
1 - 5 t |
5 |
Real
scale |
ISV plant design aimed at a reclamation
intervention on a polluted site |
0.5 MW |
>10 t |