Abstract - The paper describes a HF equivalent circuit 
for the stator winding of three-phase AC motors, valid in a wide 
frequency range. The model fitting is based on winding complex 
impedance measurements. Both the phase-to-phase and the 
phase-to-ground impedances are considered. The proposed model can 
be utilized in theoretical and numerical HF analysis of inverter-fed 
AC motors. In this case, the equivalent circuit allows to predict 
both differential- and common-mode conducted EMI. Furthermore, also 
transient effects can be predicted when the analysis is performed in 
the time domain. The numerical results, obtained by means of PSpice, 
are compared with the corresponding experimental tests in both 
frequency and time domains.